خازن استوانه ای, خازن روغنی, خازن سیلندری روغنی, خازن گازی, خازن اصلاح ضریب قدرت, رله نشتی جریان, رله ارت فالت, رله بیمارستانی

RCMS460



LINETRAXX® RCMS460-D/-L – RCMS490-D/-L
Multi-channel AC, pulsed DC and AC/DC sensitive
residual current monitors for earthed AC, DC
and AC/DC systems (TN and TT systems)

 

 

 

 

 

 

 

 

Description:

The RCMS system consists of one or more RCMS460-D/-L or RCMS490-D/-L residual current monitors, which are able to detect and evaluate fault, residual and operating currents in earthed power supplies via the related measuring current transformers. The maximum voltage of the system to be monitored depends on the nominal insulation voltage of the measuring current transformer used in the case of busbar systems, resp. depend on the cables or conductors that are routed through.
Closed W…AB series measuring current transformers are required to measure AC/DC sensitive residual currents (according to IEC/TR 60755: Type B). Six W…AB series measuring current transformers require one AN420 or AN110 power supply unit. W (closed), WR (rectangular), WS (split-core) and WF… (flexible) series measuring current transformers are used for alternating and pulsating currents (according to IEC/TR 60755: Type A).

Any combination of the various measuring current transformer series can be connected to the monitor measuring channels. Each RCMS460-D/-L and RCMS490-D/-L has 12 measuring channels. Up to 90 residual current monitors can be connected via a BMS bus (RS-485 interface with BMS protocol), thereby up to 1080 measuring channels (sub-circuits) can be monitored.

If this product is to be used for personnel, fire or plant protection, the frequency response can be set accordingly. The measured currents can be analysed for harmonics.

Application:

  • Measuring and evaluating residual, fault and rated currents of loads and installations in the frequency range of 0…2000 Hz (W…AB series measuring current transformers), 42…2000 Hz (W, WR, WS WF series measuring current transformers).

  • Monitoring of currents regarded as fire hazards in flammable atmospheres

  • EMC monitoring of TN-S systems for “stray currents” and additional N-PE connections.

  • Monitoring of N conductors for overload caused by harmonics

  • Monitoring of PE and equipotential bonding conductors to ensure they are free of current

  • Residual current monitoring of stationary electrical equipment and systems to determine test intervals which meet practical requirements in compliance with the accident prevention regulations BGV A3 (Germany).

  • Personnel and fire protection due to rapid disconnection

  • Monitoring of digital inputs

Function:

The currents are detected and evaluated as true r.m.s. values in the frequency range of 0 (42)…2000 Hz. All channels are scanned simultaneously so that the maximum scanning time for all channels is 180 ms if 1x the response value is exceeded and 30 ms if 5x the
response value is exceeded.
The current values of all channels are indicated on the LC display in bar graph format. If one of both values falls below or exceeds the set response value, the response delay ton begins. Once the response delay has expired, the common alarm relays “K1/K2” switch and the alarm LEDs 1/2 light up.
Two response values/common alarm relays, which can be set separately, allow a distinction to be made between prewarning and alarm. The faulty channel(s) and the associated measured value are indicated on the LC display. If the current exceeds or falls below the release value (response value plus hysteresis), the delay on release toff begins. Once the delay has expired, the common alarm relays return to their initial position.
If the fault memory is enabled, the common alarm relays remain in the alarm state until the reset button is pressed or a reset command is sent via the BMS bus. The device function can be tested using the test button. Parameters are assigned to the device via the LCD and the control buttons on the front of one of the connected RCMS…-D devices or via connected panels and protocol converters (e.g. COM460IP). The preset function allows the response values to be set for all channels considering the currently measured value for each channel.

Features:

  • Optional AC, pulsed DC or AC/DC sensitive measurement by selecting the respective measuring current transformer for each channel

  • True r.m.s. value measurement

  • 12 measuring channels per device for residual current measurement or digital input

  • Up to 90 RCMS… monitors, up to1080 measuring channels in the system

  • Fast parallel scanning for all channels

  • Response ranges: 10 mA…10 A (0…2000 Hz), 6 mA…20 A (42…2000 Hz), 100 mA…125 A (42…2000 Hz) RCMS…-D4

  • Preset function

  • Adjustable time delays

  • The frequency response characteristics can be set for the protection of persons, fire and plant protection

  • History memory with date and time stamp for 300 data records

  • Data logger for 300 data records/channel

  • Analysis of the harmonics, DC, THD

  • Two alarm relays with one changeover contact each

  • Device version RCMS490 with one alarm contact per channel

  • N/O or N/C operation and fault memory selectable

  • Connection external test/reset button

  • Backlit graphical display (7-segment display) and alarm LEDs

  • Data exchange via BMS bus

  • Password protection for device setting

  • Continuous CT connection monitoring

  • RoHS compliant

 

Digital input:
Each individual channel can be used for one of the following monitoring functions:
as digital input using a potential-free contact 1/0 or for current or residual current monitoring in combination with measuring current transformers.

                                          Wiring diagram:

                                          Dimentions:

 

                                         Technical data:

 

                                          Ordering information:

                                          Accessories:

  • خازن های HYDRA

    شرکت هیدرا از سال 1994 میلادی با نام تجاری AEG فعالیت خود را آغاز کرد و امروزه در هر خط تولید به شکل ماهانه بیش از 2 میلیون خازن تولید می نماید. در سال 2011 نام شرکت از AEG به HYDRA تغییر یافت و در حال حاضر برای کاهش هزینه های تولید، کارخانه شرکت در شهر Jicin می باشد. دفتر مرکزی، دپارتمان طراحی مهندسی و فروش HYDRA در برلین آلمان واقع می باشند.

    خازن های HYDRA read
  • بندر آلمان

    امروزه شرکت BENDER آلمان با تولید بیش از 2000 نوع رله حفاظتی در شاخه های محتلف صنعت برق، بعنوان یکی از شرکتهای پیشتاز و صاحب تکنولوژی در تولید انواع رله های حفاظتی در سطح دنیا مطرح میباشد.

    اطمینان از عملکرد بی وقفه سیستم و همچنین کاهش هزینه های نگهداری آن در بلند مدت از اهداف اصلی Bender هستند.

    بندر آلمان read